ORA-39083: Object type PROCACT_SYSTEM failed to create with error

Share

Error

Processing object type DATABASE_EXPORT/SYSTEM_PROCOBJACT/PRE_SYSTEM_ACTIONS/PROCACT_SYSTEM
>>> Cannot set an SCN larger than the current SCN. If a Streams Capture configuration was imported then the Apply that processes the captured messages needs to be dropp
ed and recreated. See My Oracle Support article number 1380295.1.
ORA-39083: Object type PROCACT_SYSTEM failed to create with error:

ORA-20000: Incompatible version of Workspace Manager Installed

Cause

Version of the Oracle Workspace Manager (OWM) in the source and target are not same.

Solution

Ignore the following errors, if IMPDP is importing all other components and data successfully:

To move the workspaces from the 11.2.0.3 or 11.2.0.4 SOURCE db, the FULL db export must be generated with the parameter “VERSION=12”.

If the SOURCE database is older than 11.2.0.3, e.g. 11.2.0.2 or 11.1.0.7, the database will first need to be upgraded to 11.2.0.3 or 11.2.0.4